Buy Micro-Epsilon ILD1302-100 Online
Safety
Knowledge of the operating instructions is a prerequisite for sensor operation.
1.1 Symbols Used
The following symbols are used in this instruction manual:
i
1.2 Warnings
Indicates a hazardous situation which, if not avoided, may result in minor or moder- ate injury.
Indicates a situation which, if not avoided, may lead to property damage.
Indicates an user action. Indicates an user tip.
Avoid unnecessary laser exposure to the human body
- – Turn off the sensor for cleaning and maintenance.
- – Turn off the sensor for system maintenance and repair if the sensor is integrated into a system.
Caution – use of controls or adjustments or performance of procedures other than those specified may cause harm.
- Connect the power supply and the display/output device in accordance with the safety regulations for electri- cal equipment.
> Danger of injury, damage to or destruction of the sensor The power supply may not exceed the specified limits.
> Danger of injury, damage to or destruction of the sensorAvoid shock and vibration to the sensor.Damage to or destruction of the sensor
Avoid continuous exposure to fluids.
> Damage to or destruction of the sensorAvoid contact with aggressive materials (washing agent, penetrating liquids or similar). > Damage to or destruction of the sensor
CE Compliance
The following applies to the optoNCDT1302: EMC regulation 2004/108/EC
Products which carry the CE mark satisfy the requirements of the EMC regulation 2004/108/EC ‘Electromag- netic Compatibility’ and the European standards (EN) listed therein. The EC declaration of conformity is kept available according to EC regulation, article 10 by the authorities responsible at
MICRO-EPSILON Messtechnik GmbH & Co. KG Königbacher Straße 15
D-94496 OrtenburgThe sensor is in compliance with the following standards
- – EN 61326-1:2006-10
- – DIN EN 55011: 2007-11 (Group 1, Class B)
- – EN 61000-6-2: 2006-03
The sensor fulfills the specification of the EMC requirements, if the instructions in the operating manual are followed.
1.4 Proper Use
- – The series optoNCDT1302 measuring system is designed for use in industrial areas.
- – It is used
for measuring displacement, distance, position and thickness
for in-process quality control and dimensional testing
- – The measuring system may only be operated within the limits specified in the technical
data, see Chap. 3.3. The sensor should only be used in such a way that in case of malfunctions or failure
personnel or machinery are not endangered.
- – Additional precautions for safety and damage prevention must be taken for safety-related applications.
1.5
Buy Micro-Epsilon ILD1302-100 OnlineProper Environment
Protection class sensor: IP 67
Optical surfaces are excluded from protection class. Contamination of the lenses leads to impairment or failure of the function.During operation of the sensor the pertinent regulations acc. to EN 60825-1 on „radiation safety of laser equipment“ must be fully observed at all times. The sensor complies with all applicable laws for the manufac- turer of laser devices.
Do not look directly into the laser beam! Possible injury of the eyes. Close your eyes or turn away promptly
if laser radiation strikes your eyes.
teach in
laser on state
optoNCDT
Buy Micro-Epsilon ILD1302-100 OnlineoptoNCDT 1302
Page 10
LASER RADIATION
Do not stare into the beam CLASS 2 LASER PRODUCT IEC 60825-1: 2007 P≤1mW; =670 nm
Laser spot
Fig. 1 True reproduction of the sensor with its actual location of the warning labels
Laser operation is indicated by LED.
Although the laser output is low looking directly into the laser beam must be avoided. Due to the visible light beam eye protection is ensured by the natural blink reflex.
The housing of the optical sensors optoNCDT1302 may only be opened by the manufacturer, see Chap. 14.. For repair and service purposes the sensors must always be sent to the manufacturer.
Buy Micro-Epsilon ILD1302-100 OnlineMicro-Epsilon ILD1302-100 For Sale Online